cveSiemensCVE-2022-23448
HistoryApr 12, 2022 - 9:15 a.m.

CVE-2022-23448

2022-04-1209:15:14
CWE-732
siemens
web.nvd.nist.gov
61
vulnerability
simatic energy manager basic
simatic energy manager pro
code execution
permissions
nvd
cve-2022-23448

CVSS2

7.2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

CVSS3

7.8

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

AI Score

7.6

Confidence

High

EPSS

0

Percentile

12.6%

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.

Affected configurations

Nvd
Node
siemenssimatic_energy_manager_basicRange<7.3
OR
siemenssimatic_energy_manager_basicMatch7.3-
OR
siemenssimatic_energy_manager_proRange<7.3
OR
siemenssimatic_energy_manager_proMatch7.3-
VendorProductVersionCPE
siemenssimatic_energy_manager_basic*cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*
siemenssimatic_energy_manager_basic7.3cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*
siemenssimatic_energy_manager_pro*cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*
siemenssimatic_energy_manager_pro7.3cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*

CNA Affected

[
  {
    "product": "SIMATIC Energy Manager Basic",
    "vendor": "Siemens",
    "versions": [
      {
        "status": "affected",
        "version": "All versions < V7.3 Update 1"
      }
    ]
  },
  {
    "product": "SIMATIC Energy Manager PRO",
    "vendor": "Siemens",
    "versions": [
      {
        "status": "affected",
        "version": "All versions < V7.3 Update 1"
      }
    ]
  }
]

CVSS2

7.2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

CVSS3

7.8

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

AI Score

7.6

Confidence

High

EPSS

0

Percentile

12.6%