Lucene search

K
cveIcscertCVE-2021-27408
HistoryJun 11, 2021 - 5:15 p.m.

CVE-2021-27408

2021-06-1117:15:10
CWE-125
icscert
web.nvd.nist.gov
43
6
cve-2021-27408
information leakage
out-of-bounds read
arbitrary code execution
nvd
information security

CVSS2

5

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

EPSS

0.002

Percentile

57.2%

The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).

Affected configurations

Nvd
Node
hillromconnex_central_stationRange<1.8.6
OR
hillromconnex_device_integration_suite_network_connectivity_engineRange<5.3
OR
hillromconnex_integrated_wall_systemRange<2.43.02
OR
hillromconnex_spot_monitorRange<1.52
OR
hillromconnex_vital_signs_monitorRange<2.43.02
OR
hillromservice_monitorRange<1.7.0.0
OR
hillromservice_toolRange<1.10
OR
hillromsoftware_development_kitRange<3.2
OR
hillromspot_vital_signs_4400Range<1.11.00-
OR
hillromspot_vital_signs_4400Range<1.11.00extended_care
VendorProductVersionCPE
hillromconnex_central_station*cpe:2.3:a:hillrom:connex_central_station:*:*:*:*:*:*:*:*
hillromconnex_device_integration_suite_network_connectivity_engine*cpe:2.3:a:hillrom:connex_device_integration_suite_network_connectivity_engine:*:*:*:*:*:*:*:*
hillromconnex_integrated_wall_system*cpe:2.3:a:hillrom:connex_integrated_wall_system:*:*:*:*:*:*:*:*
hillromconnex_spot_monitor*cpe:2.3:a:hillrom:connex_spot_monitor:*:*:*:*:*:*:*:*
hillromconnex_vital_signs_monitor*cpe:2.3:a:hillrom:connex_vital_signs_monitor:*:*:*:*:*:*:*:*
hillromservice_monitor*cpe:2.3:a:hillrom:service_monitor:*:*:*:*:*:*:*:*
hillromservice_tool*cpe:2.3:a:hillrom:service_tool:*:*:*:*:*:*:*:*
hillromsoftware_development_kit*cpe:2.3:a:hillrom:software_development_kit:*:*:*:*:*:*:*:*
hillromspot_vital_signs_4400*cpe:2.3:a:hillrom:spot_vital_signs_4400:*:*:*:*:-:*:*:*
hillromspot_vital_signs_4400*cpe:2.3:a:hillrom:spot_vital_signs_4400:*:*:*:*:extended_care:*:*:*

CNA Affected

[
  {
    "product": "Welch Allyn medical device management tools",
    "vendor": "n/a",
    "versions": [
      {
        "status": "affected",
        "version": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
      }
    ]
  }
]

Social References

More

CVSS2

5

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

EPSS

0.002

Percentile

57.2%