Lucene search

K
cve[email protected]CVE-2021-22703
HistoryFeb 19, 2021 - 4:15 p.m.

CVE-2021-22703

2021-02-1916:15:13
CWE-319
web.nvd.nist.gov
29
3
cve-2021-22703
cwe-319
powerlogic ion7400
powerlogic ion7650
powerlogic ion83xx
powerlogic ion84xx
powerlogic ion85xx
powerlogic ion8600
powerlogic ion8650
powerlogic ion8800
powerlogic ion9000
pm800
information security
cleartext transmission
sensitive information disclosure
http network traffic

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

7.3 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

45.5%

A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device.

Affected configurations

NVD
Node
schneider-electricpowerlogic_ion7400_firmwareRange<3.0.0
AND
schneider-electricpowerlogic_ion7400Match-
Node
schneider-electricpowerlogic_ion7650_firmware
AND
schneider-electricpowerlogic_ion7650Match-
Node
schneider-electricpowerlogic_ion8600_firmware
AND
schneider-electricpowerlogic_ion8600Match-
Node
schneider-electricpowerlogic_ion8650_firmwareRange4.31.2
AND
schneider-electricpowerlogic_ion8650Match-
Node
schneider-electricpowerlogic_ion8800_firmware
AND
schneider-electricpowerlogic_ion8800Match-
Node
schneider-electricpowerlogic_ion9000_firmwareRange<3.0.0
AND
schneider-electricpowerlogic_ion9000Match-
Node
schneider-electricpowerlogic_pm8000_firmwareRange<3.0.0
AND
schneider-electricpowerlogic_pm8000Match-
Node
schneider-electricpowerlogic_ion8300_firmware
AND
schneider-electricpowerlogic_ion8300Match-
Node
schneider-electricpowerlogic_ion8400_firmware
AND
schneider-electricpowerlogic_ion8400Match-
Node
schneider-electricpowerlogic_ion8500_firmware
AND
schneider-electricpowerlogic_ion8500Match-

CNA Affected

[
  {
    "product": "PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)",
    "vendor": "n/a",
    "versions": [
      {
        "status": "affected",
        "version": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior."
      }
    ]
  }
]

Social References

More

5 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:N/C:P/I:N/A:N

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

7.3 High

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

45.5%