Lucene search

K
cve[email protected]CVE-2020-5653
HistoryNov 02, 2020 - 9:15 p.m.

CVE-2020-5653

2020-11-0221:15:33
CWE-120
web.nvd.nist.gov
25
cve-2020-5653
buffer overflow
melsec iq-r
firmware
tcp/ip
remote attack
network security
vulnerability

7.5 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:P/I:P/A:P

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

9.4 High

AI Score

Confidence

High

0.004 Low

EPSS

Percentile

74.7%

Buffer overflow vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are ‘02’ or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are ‘01’ or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are ‘08’ or before, RD81MES96N MES Interface Module First 2 digits of serial number are ‘04’ or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are ‘04’ or before) allows a remote unauthenticated attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet.

Affected configurations

NVD
Node
mitsubishielectricmelsec_iq-rj71eip91_firmwareMatch-
AND
mitsubishielectricmelsec_iq-rj71eip91Match-
Node
mitsubishielectricmelsec_iq-rj71pn92_firmwareMatch-
AND
mitsubishielectricmelsec_iq-rj71pn92Match-
Node
mitsubishielectricmelsec_iq-rd81dl96_firmwareMatch-
AND
mitsubishielectricmelsec_iq-rd81dl96Match-
Node
mitsubishielectricmelsec_iq-rd81mes96n_firmwareMatch-
AND
mitsubishielectricmelsec_iq-rd81mes96nMatch-
Node
mitsubishielectricmelsec_iq-rd81opc96_firmwareMatch-
AND
mitsubishielectricmelsec_iq-rd81opc96Match-

CNA Affected

[
  {
    "product": "MELSEC iQ-R series",
    "vendor": "Mitsubishi Electric Corporation",
    "versions": [
      {
        "status": "affected",
        "version": "RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before, RD81DL96 High Speed Data Logger Module First 2 digits of serial number are '08' or before, RD81MES96N MES Interface Module First 2 digits of serial number are '04' or before, and RD81OPC96 OPC UA Server Module First 2 digits of serial number are '04' or before"
      }
    ]
  }
]

7.5 High

CVSS2

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:P/I:P/A:P

9.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

9.4 High

AI Score

Confidence

High

0.004 Low

EPSS

Percentile

74.7%