Lucene search

K
cve[email protected]CVE-2018-7781
HistoryJul 03, 2018 - 2:29 p.m.

CVE-2018-7781

2018-07-0314:29:01
CWE-311
web.nvd.nist.gov
19
schneider electric
pelco sarix
camera
firmware
vulnerability
cve-2018-7781
nvd

8.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

8.5 High

AI Score

Confidence

High

4 Medium

CVSS2

Access Vector

Access Complexity

Authentication

SINGLE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:S/C:P/I:N/A:N

0.001 Low

EPSS

Percentile

42.8%

In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.

Affected configurations

NVD
Node
schneider-electricimps110-1_firmwareRange<3.29.69
AND
schneider-electricimps110-1Match-
Node
schneider-electricimps110-1e_firmwareRange<3.29.69
AND
schneider-electricimps110-1eMatch-
Node
schneider-electricimps110-1er_firmwareRange<3.29.69
AND
schneider-electricimps110-1erMatch-
Node
schneider-electricibps110-1er_firmwareRange<3.29.69
AND
schneider-electricibps110-1erMatch-
Node
schneider-electricimp1110-1_firmwareRange<3.29.69
AND
schneider-electricimp1110-1Match-
Node
schneider-electricimp1110-1e_firmwareRange<3.29.69
AND
schneider-electricimp1110-1eMatch-
Node
schneider-electricimp1110-1er_firmwareRange<3.29.69
AND
schneider-electricimp1110-1erMatch-
Node
schneider-electricibp1110-1er_firmwareRange<3.29.69
AND
schneider-electricibp1110-1erMatch-
Node
schneider-electricimp219-1_firmwareRange<3.29.69
AND
schneider-electricimp219-1Match-
Node
schneider-electricimp219-1e_firmwareRange<3.29.69
AND
schneider-electricimp219-1eMatch-
Node
schneider-electricimp219-1er_firmwareRange<3.29.69
AND
schneider-electricimp219-1erMatch-
Node
schneider-electricibp219-1er_firmwareRange<3.29.69
AND
schneider-electricibp219-1erMatch-
Node
schneider-electricimp319-1_firmwareRange<3.29.69
AND
schneider-electricimp319-1Match-
Node
schneider-electricimp319-1e_firmwareRange<3.29.69
AND
schneider-electricimp319-1eMatch-
Node
schneider-electricimp319-1er_firmwareRange<3.29.69
AND
schneider-electricimp319-1erMatch-
Node
schneider-electricibp319-1er_firmwareRange<3.29.69
AND
schneider-electricibp319-1erMatch-
Node
schneider-electricimp519-1_firmwareRange<3.29.69
AND
schneider-electricimp519-1Match-
Node
schneider-electricimp519-1e_firmwareRange<3.29.69
AND
schneider-electricimp519-1eMatch-
Node
schneider-electricimp519-1er_firmwareRange<3.29.69
AND
schneider-electricimp519-1erMatch-
Node
schneider-electricibp519-1er_firmwareRange<3.29.69
AND
schneider-electricibp519-1erMatch-

CNA Affected

[
  {
    "product": "Pelco Sarix Professional V1",
    "vendor": "Schneider Electric SE",
    "versions": [
      {
        "status": "affected",
        "version": "Pelco Sarix Pro 1 st generation with firmware versions prior to 3.29.69"
      }
    ]
  }
]

8.8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

8.5 High

AI Score

Confidence

High

4 Medium

CVSS2

Access Vector

Access Complexity

Authentication

SINGLE

Confidentiality Impact

PARTIAL

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:S/C:P/I:N/A:N

0.001 Low

EPSS

Percentile

42.8%

Related for CVE-2018-7781