Lucene search

K
cve[email protected]CVE-2017-6780
HistorySep 07, 2017 - 9:29 p.m.

CVE-2017-6780

2017-09-0721:29:00
CWE-770
CWE-399
web.nvd.nist.gov
21
cve-2017-6780
cisco
iot-fnd
vulnerability
tcp
memory exhaustion
denial of service
nvd
cscvc77164

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

7.8 High

CVSS2

Access Vector

Access Complexity

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:N/I:N/A:C

0.001 Low

EPSS

Percentile

48.0%

A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to cause the system to consume additional memory, eventually forcing the device to restart, aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed, the system will restart, creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System, if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director, if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164.

Affected configurations

NVD
Node
ciscoconnected_grid_network_management_systemRange3.0\(0.54\)
OR
ciscoiot_field_network_directorRange3.2.0-182

CNA Affected

[
  {
    "product": "Cisco IoT Field Network Director",
    "vendor": "n/a",
    "versions": [
      {
        "status": "affected",
        "version": "Cisco IoT Field Network Director"
      }
    ]
  }
]

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

7.8 High

CVSS2

Access Vector

Access Complexity

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

COMPLETE

AV:N/AC:L/Au:N/C:N/I:N/A:C

0.001 Low

EPSS

Percentile

48.0%

Related for CVE-2017-6780